4.4 Article

Continuous Countercurrent Tangential Chromatography for Monoclonal Antibody Purification

期刊

SEPARATION SCIENCE AND TECHNOLOGY
卷 48, 期 9, 页码 1289-1297

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/01496395.2013.767837

关键词

chromatography; downstream processing; hollow fiber membrane; monoclonal antibody; protein A; protein purification

资金

  1. NIH SBIR from the National Institute of General Medical Sciences [GRANT10756648]
  2. Ben Franklin Technology Partners of Central PA

向作者/读者索取更多资源

Recent increases in antibody titers have generated renewed interest in lower-cost continuous chromatographic processes for antibody purification. The objective of this study was to design, build, and test a continuous countercurrent tangential chromatography system in which the resin (in the form of a slurry) flows sequentially through a series of static mixers and hollow fiber membrane modules to accomplish the binding, washing, elution, stripping, and equilibration steps in continuous operation with true countercurrent staging. Experimental studies were performed for the purification of an IgG(4) monoclonal antibody from a model feed containing bovine serum albumin and myoglobin using a protein A affinity resin. Batch uptake / desorption experiments were used in combination with critical flux filtration data to design the continuous countercurrent tangential chromatography system. The process was stable during continuous operation, providing the IgG(4) at 94% yield with greater than 97% purity. The antibody productivity was more than 40g protein per liter of resin per hour, which is significantly greater than can be obtained using conventional packed columns. The results clearly demonstrate the potential of using continuous countercurrent tangential chromatography for large-scale antibody purification.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据