4.7 Article

Dissolved O2 sensor based on cobalt(II) phthalocyanine immobilized in situ on electrically conducting carbon ceramic mesoporous SiO2/C material

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 177, 期 -, 页码 231-238

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2012.10.110

关键词

Carbon ceramic material; Cobalt phthalocyanine; Dissolved oxygen sensor; Sol-gel

资金

  1. FAPESP
  2. CNPq
  3. INCTBio
  4. CAPES
  5. CNPq/TWAS

向作者/读者索取更多资源

This work describes the preparation of mesoporous carbon ceramics SiO2/50 wt.% C (S-BET = 170 m(2) g(-1)), where C is graphite, by the sol-gel method. This material was used as a matrix to support cobalt phthalocyanine (CoPc), prepared in situ on their surface, to assure homogeneous dispersion of the electrocatalyst complex in the pores of the matrix. Pressed disk electrode made with SiO2/C/CoPc was used to analyze dissolved oxygen in water by an electrochemical technique in neutral media and dissolved O-2 was reduced at -0.23 V. The linear response range, sensitivity and detection limit obtained were 0.5-6.6 mg L-1, 2.16 mu A L mg(-1) and 0.01 mg L-1, respectively, by chronoamperometry. A mechanism involving two electrons in O-2 reduction was determined by cyclic voltammetry technique. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation was 1.6% for 10 measurements of a solution of 6.5 mg L-1 oxygen. The sensor was applied to determine oxygen in pond and tap water samples showing to be a promising tool for this purpose. (c) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据