4.7 Article

Nerve agent simulant detection by solidly mounted resonators (SMRs) polymer coated using laser induced forward transfer (LIFT) technique

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 173, 期 -, 页码 32-39

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2012.04.061

关键词

Solidly mounted resonator; Electro-acoustic sensor; Gas sensor; DMMP; LIFT; Polymer deposition

资金

  1. European Commission [247868, 982671]

向作者/读者索取更多资源

Novel chemical sensor based on film bulk acoustic resonators (FBARs), in the solidly mounted resonator (SMR) configuration, exploiting three polymer sensitive layers deposited by laser-induced forward transfer (LIFT) are reported. The resonators operate at a frequency of 2 GHz and consist of a piezoelectric aluminium nitride film sandwiched between two metal electrodes deposited on a silicon substrate with an acoustic Bragg reflector at the interface to ensure the acoustic insulation. Chemically sensitive polymers, i.e. polyepichlorohydrin (PECH), polyethyleneimine (PEI), and polyisobutylene (FIB), are applied by LIFT onto the SMRs. In order to improve the process efficiency, and to protect the polymer materials from the energetic laser pulses, a triazene polymer, acting as a dynamic release layer (DRL) was used. Upon exposure to different concentrations of dimethyl methyl phosphonate (DMMP) vapour, the polymer coated sensors show fast and reversible responses, with a sensitivity between 239 and 405 Hz/ppm. Our findings, i.e. the use of LIFT in conjunction with highly sensitive, robust, and reliable SMR transducers show that this approach is well-suited to implement chemical sensor arrays. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据