期刊
SENSORS AND ACTUATORS B-CHEMICAL
卷 155, 期 1, 页码 253-257出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2010.12.011
关键词
Fluorescence; Chemosensor; Cysteine; Naphthalimide
资金
- National Natural Science Foundation of China [21005068]
- State Key Laboratory of Chemo/Biosensing and Chemometrics Foundation [200906]
- Xiangtan University
Naphthalimide derivative (compound 1)containing hydrophilic hexanoic acid group was synthesized and used to recognize cysteine (Cys) in aqueous solution. The fluorescence enhancement of 1 was attributed to the cyclization reaction of 1 with Cys by 1:1 binding stoichiometry, which has been utilized as the basis of fabrication of the Cys-sensitive fluorescent chemosensor. The comparison of this method with some other fluorescence methods for the determination of Cys indicated that the methods can be applied in aqueous solution rather than organic solution. The analytical performance characteristics of the proposed Cys-sensitive chemosensor were investigated. The chemosensor can be applied to the quantification of Cys with a linear range covering from 3.9 x 10(-8) to 1.4 x 10(-5) M and a detection limit of 7.8 x 10(-9) M. And the chemosensor shows excellent selectivity for Cys over other amino acids. Moreover, the response of the chemosensor toward Cys is fast (response time less than 3 min). In addition, the chemosensor has been used for determination of Cys in serum samples with satisfactory results. (C) 2010 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据