4.7 Article

Humidity sensors based on polyaniline nanofibres

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 143, 期 2, 页码 530-534

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2009.09.050

关键词

Conducting polymer; Polyaniline; Humidity sensor; Polymer swelling; PAni nanofibres

资金

  1. National Natural Science Foundation of China [50372011, 50973013]
  2. Natural Science Foundation of Liaoning Province, China [20052016]
  3. China-Ireland Collaboration Funding

向作者/读者索取更多资源

Humidity sensor based on polyaniline nanofibres was fabricated and its response to humidity was investigated. It was found that the sensor behaved differently compared to commonly known conducting polymer based sensors. The sensor responded to low relative humidity (<50% RH) normally by decreasing electrical resistance with increasing humidity. However, at higher RH the sensor reversed its responses by increasing the electrical resistance with humidity. It is believed that the unique Structure of nanofibres, which is more susceptible to distortion during polymer swelling, is responsible for the 'reversed behaviour'. IR data confirmed that excess water absorption occurred and that a change in polymer oxidation state might also have taken place. (C) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据