4.7 Article

Virgin olive oil sensory evaluation by an artificial olfactory system, based on Quartz Crystal Microbalance (QCM) sensors

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 147, 期 1, 页码 159-164

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2010.01.071

关键词

QCM gas sensor; Electronic nose; Virgin olive oil (VOO); Sensory evaluation; Principal Component Analysis (PCA); Chromatographic adsorbents

资金

  1. Andalusia Regional Government, Spain
  2. Spanish Ministry of Science [RTA 04-128]

向作者/读者索取更多资源

The potential of an artificial olfactory system, constituted by an array of five Quartz Crystal Microbalance (QCM) sensors, to discriminate virgin olive oil samples based on their aromatic profiles was researched. Five gas chromatographic stationary phases (OV-17, OV-275, PEG, Span 80 and Vaseline) were employed as sensing films of QCM sensors. The steady state sensor responses measured by a statistical measurement system were used to evaluate the discrimination properties of the system by Principal Component Analysis (PCA) method. The results of this study provide promising perspectives for the use of a low-cost, easy to use and fast system for the differentiation of edible from lampante virgin olive oils. (c) 2010 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据