4.6 Article

Enzyme Immobilization Strategies and Electropolymerization Conditions to Control Sensitivity and Selectivity Parameters of a Polymer-Enzyme Composite Glucose Biosensor

期刊

SENSORS
卷 10, 期 7, 页码 6439-6462

出版社

MDPI
DOI: 10.3390/s100706439

关键词

hydrogen peroxide; polyphenylenediamine; amperometry; enzyme-modified electrode; ascorbic acid interference; brain monitoring

资金

  1. Irish Research Council for Science, Engineering and Technology (IRCSET)
  2. Science Foundation Ireland [04/BR/C0198]
  3. Science Foundation Ireland (SFI) [04/BR/C0198] Funding Source: Science Foundation Ireland (SFI)

向作者/读者索取更多资源

In an ongoing programme to develop characterization strategies relevant to biosensors for in-vivo monitoring, glucose biosensors were fabricated by immobilizing the enzyme glucose oxidase (GOx) on 125 mu m diameter Pt cylinder wire electrodes (Pt-C), using three different methods: before, after or during the amperometric electrosynthesis of poly(ortho-phenylenediamine), PoPD, which also served as a permselective membrane. These electrodes were calibrated with H2O2 (the biosensor enzyme signal molecule), glucose, and the archetypal interference compound ascorbic acid (AA) to determine the relevant polymer permeabilities and the apparent Michaelis-Menten parameters for glucose. A number of selectivity parameters were used to identify the most successful design in terms of the balance between substrate sensitivity and interference blocking. For biosensors electrosynthesized in neutral buffer under the present conditions, entrapment of the GOx within the PoPD layer produced the design (Pt-C/PoPD-GOx) with the highest linear sensitivity to glucose (5.0 +/- 0.4 mu A cm(-2) mM(-1)), good linear range (K-M = 16 +/- 2 mM) and response time (< 2 s), and the greatest AA blocking (99.8% for 1 mM AA). Further optimization showed that fabrication of Pt-C/PoPD-GOx in the absence of added background electrolyte (i.e., electropolymerization in unbuffered enzyme-monomer solution) enhanced glucose selectivity 3-fold for this one-pot fabrication protocol which provided AA-rejection levels at least equal to recent multi-step polymer bilayer biosensor designs. Interestingly, the presence of enzyme protein in the polymer layer had opposite effects on permselectivity for low and high concentrations of AA, emphasizing the value of studying the concentration dependence of interference effects which is rarely reported in the literature.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据