期刊
SENSORS
卷 9, 期 11, 页码 8579-8592出版社
MDPI
DOI: 10.3390/s91108579
关键词
fault detection; directed graph; reliability; false alarm; missed alarm
资金
- National Natural Science Foundation of China [60736026, 60904044]
- China Postdoctoral Science Foundation [20080440386]
- NSERC (Natural Sciences and Engineering Research Council of Canada)
To improve fault detection reliability, sensor location should be designed according to an optimization criterion with constraints imposed by issues of detectability and identifiability. Reliability requires the minimization of undetectability and false alarm probability due to random factors on sensor readings, which is not only related with sensor readings but also affected by fault propagation. This paper introduces the reliability criteria expression based on the missed/false alarm probability of each sensor and system topology or connectivity derived from the directed graph. The algorithm for the optimization problem is presented as a heuristic procedure. Finally, a boiler system is illustrated using the proposed method.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据