Quantification of total element concentrations in soils using total X-ray fluorescence spectroscopy (TXRF)

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 463, 期 -, 页码 374-388

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2013.05.068

关键词

Total X-ray fluorescence spectroscopy; Calibration; Validation; Total elements; Rapid soil analysis

资金

  1. World Agroforestry Centre (ICRAF)
  2. Bill 82 Melinda Gates Foundation
  3. Dr. Hermann Eiselen Ph.D. Grant from the Foundation fiat panis
  4. Food Security Centre at the University of Hohenheim, Germany
  5. Deutscher Akademischer Austausch Dienst (DAAD)

向作者/读者索取更多资源

Total X-ray fluorescence spectroscopy (TXRF) determines concentrations of major and trace elements in multiple media. We developed and tested a method for the use of TXRF for direct quantification of total element concentrations in soils using an S2 PICOFOX (TM) spectrometer (Bruker AXS Microanalysis GmbH, Germany). We selected 15 contrasting soil samples from across sub-Saharan Africa for element analysis to calibrate the instrument against concentrations determined using the inductively coupled plasma-mass spectroscopy (ICP-MS) standard method. A consistent underestimation of element concentrations using TXRF compared to ICP-MS reference analysis occurred, indicating that spectrometer recalibration was required. Single-element recalibration improved the TXRF spectrometer's sensitivity curve. Subsequent analysis revealed that TXRF determined total element concentrations of Al, K, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, and Ga accurately (model efficacy/slope close to 1:1 line, and R-2 > 0.80) over a wide range of soil samples. Other elements that could be estimated with an acceptable precision (R-2 > 0.60) compared with ICP-MS although generally somewhat under- or overestimated were P, Ca, As, Rb, Sr, Y, Pr, Ta and Pb. Even after recalibration, compared to ICP-MS the TXRF spectrometer produced underestimations for elements Na, Mg, Ba, Ce, Hf, La, Nd, W and Sm and overestimations for elements Bi, TI and Zr. We validated the degree of accuracy of the TXRF analytical method after recalibration using an independent set of 20 soil samples. We also tested the accuracy of the analysis using 2 multi-element standards as well as the method repeatability on replicate samples. The resulting total element concentration repeatability for all elements analyzed were within 10% coefficient of variability after the instrument recalibration except for Cd and TI. Our findings demonstrate that TXRF could be used as a rapid screening tool for total element concentrations in soils assuming that sufficient calibration measures are followed. (C) 2013 The Authors. Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据