4.5 Article

Arc pressure and fluid flow during alternating shielding gases. Part 2: arc force determination

期刊

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1179/1362171813Y.0000000141

关键词

GTAW; Arc pressure; Arc forces; Shielding gases; Alternating shielding gases

资金

  1. BAE Systems Surface Ships Limited

向作者/读者索取更多资源

The transient variation of the shielding gas present in the alternating shielding gas process produces a dynamic action within the liquid weld metal. Flow vectors opposite in direction have been reported due to the various forces acting on the weld metal when argon and helium are present; however, no data have been provided to substantiate this claim. This part of the study evaluates the various forces acting on the liquid weld metal when using argon and helium, and their effects are discussed. It was determined that argon produces a greater vertically downward force in the central region than does helium for both the arc force and Lorentz force. However, helium produces a greater radially outward force at the pool surface than does argon due to plasma shear stress and Marangoni convection. In addition, the buoyancy force, i.e. the vertically upward force in the central portion of the weld metal, was greater for helium.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据