Overall and local movement speeds during fire drill evacuations in buildings up to 31 stories

期刊

SAFETY SCIENCE
卷 50, 期 8, 页码 1655-1664

出版社

ELSEVIER
DOI: 10.1016/j.ssci.2012.01.003

关键词

Evacuation; Egress; Fire safety; Modeling; Theory

向作者/读者索取更多资源

The time that it takes an occupant population to reach safety when descending a stairwell during building evacuations is typically described by measurable engineering variables such as stairwell geometry, speed, density, and pre-evacuation delay. In turn, engineering models of building evacuation use these variables to predict the performance of egress systems for building design, emergency planning, or event reconstruction. As part of a program to better understand occupant movement and behavior during building emergencies, the Engineering Laboratory at the National Institute of Standards and Technology (NIST) has been collecting stairwell movement data during fire drill evacuations of office buildings. These data collections are intended to provide a better understanding of this principal building egress feature and develop a technical foundation for future codes and standards requirements. To date, NIST has collected fire drill evacuation data in eight office building occupancies ranging from 6 to 62 stories in height that have included a range of stairwell widths and occupant densities. While average movement speeds in the current study of 0.48 m/s +/- 0.16 m/s are observed to be quite similar to the range of literature values, local movement speeds as occupants traverse down the stairwell are seen to vary widely within a given stairwell, ranging from 0.056 m/s to 1.7 m/s. These data should provide confirmation of the adequacy of existing literature values typically used for occupant movement speeds or provide updated values for future analyses. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据