4.2 Article

Solid phase extraction of trace amount of Cu(II) using functionalized-graphene

期刊

RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A
卷 87, 期 11, 页码 1851-1858

出版社

MAIK NAUKA/INTERPERIODICA/SPRINGER
DOI: 10.1134/S0036024413110253

关键词

Cu(II); SPE; octadecyl slica disks; FAAS; porphyrin-graphene nanohybrid; 5-(4-aminophenyl)-10,15,20-triphenyl porphyrin (TPP) and grapheme oxide molecules covalently bonded together via an amide bond (TPP-NHCO-SPFGraphene)

资金

  1. Chemistry Department of Varamin (Pishva) branch Islamic Azad University
  2. East Tehran branch Islamic Azad University

向作者/读者索取更多资源

A novel and selective method for the fast determination of trace amounts of Cu(II) ions in water samples has been developed. The first organic-solution-processable functionalized-graphene (SPF-Graphene) hybrid material with porphyrins, porphyrin-graphene nanohybrid, 5-(4-aminophenyl)-10, 15, 20-triphenyl porphyrin and its photophysical properties including optical (TPP) and grapheme oxide molecules covalently bonded together via an amide bond (TPP-NHCO-SPFGraphene) were used as absorbent for extraction of Cu(II) ions by solid phase extraction method. The complexes were eluted with HNO3 (2 M) 10% (vol/vol) methanol in acetone and determined the analyte by flame atomic absorption spectrometry. The procedure is based on the selective formation of Cu(II) at optimum pH by elution with organic eluents and determination by flame atomic absorption spectrometry. The method is based on complex formation on the surface of the ENVI-18 DISK (TM) disks modified porphyrin-graphene nanohybrid, 5-(4-aminophenyl)-10,15,20-triphenyl porphyrin (TPP) and grapheme oxide molecules covalently bonded together via an amide bond (TPP-NHCO-SPFGraphene) followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution is efficient and quantitative. The effect of potential interfering ions, pH, TPP-NHCO-SPFGraphene, amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break-through volume was found to about 1000 mL providing a preconcentration factor of 600. The maximum capacity of the disks was found to be 398 +/- 3 mu g for Cu2+. The limit of detection of the proposed method is 5 ng per 1000 mL. The method was applied to the extraction and recovery of copper in different water samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据