4.5 Article

A velocity map imaging detector with an integrated gas injection system

期刊

REVIEW OF SCIENTIFIC INSTRUMENTS
卷 80, 期 3, 页码 -

出版社

AMER INST PHYSICS
DOI: 10.1063/1.3085799

关键词

beam handling techniques; ion optics; Monte Carlo methods; photon-nucleus reactions; xenon; yttrium compounds

资金

  1. Stichting voor Fundamenteel Onderzoek der Materie (FOM)
  2. Nederlandse organisatie voor Wetenschappelijk Onderzoek (NWO)
  3. Max-Planck Society
  4. German Science Foundation (DFG)
  5. Swedish Research Council

向作者/读者索取更多资源

We present the design of a velocity map imaging spectrometer where the target gas is injected from a capillary that is integrated in the repeller plate of the ion optics assembly that drives electrons/ions formed by ionization or dissociation to a two-dimensional detector. The geometry of this design allows the use of gas densities in the interaction region that are two to three orders of magnitude higher than the densities that are used in standard velocity map imaging spectrometers, making the detector suitable for working with weak light sources such as newly developed attosecond pulse sources, or (quasi-)cw sources such as synchrotrons. In a test where monoenergetic photoelectrons were generated by six-photon ionization of Xe (utilizing the second harmonic of a neodymium doped Nd:YAG), the kinetic energy resolution of the spectrometer was found to be Delta E/E=1.8%. This number was found to be in good agreement with Monte Carlo simulations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据