RELEASE AND VELOCITY OF MICRONIZED DEXAMETHASONE IMPLANTS WITH AN INTRAVITREAL DRUG DELIVERY SYSTEM Kinematic Analysis With a High-Speed Camera

期刊

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/IAE.0b013e31825699e5

关键词

release; velocity; drug delivery; high-speed camera; kinematic analysis

资金

  1. Deutsche Forschungsgemeinschaft (DFG) Graduiertenkolleg [GRK1572]

向作者/读者索取更多资源

Purpose: Ozurdex, a novel dexamethasone (DEX) implant, is released by a drug delivery system into the vitreous cavity. We analyzed the mechanical release aperture of the novel applicator, obtained real-time recordings using a high-speed camera system and performed kinematic analysis of the DEX application. Design: Experimental study. Methods: The application of intravitreal DEX implants (6 mm length, 0.46 mm diameter; 700 mu g DEX mass, 0.0012 g total implant mass) was recorded by a high-speed camera (500 frames per second) in water (Group A: n = 7) or vitreous (Group B: n = 7) filled tanks. Kinematic analysis calculated the initial muzzle velocity as well as the impact on the retinal surface at approximately 15 mm of the injected drug delivery system implant in both groups. A series of drug delivery system implant positions was obtained and graphically plotted over time. Results: High-speed real-time recordings revealed that the entire movement of the DEX implant lasted between 28 milliseconds and 55 milliseconds in Group A and 1 millisecond and 7 milliseconds in Group B. The implants moved with a mean muzzle velocity of 820 +/- 350 mm/s (+/- SD, range, 326-1,349 mm/s) in Group A and 817 +/- 307 mm/s (+/- SD, range, 373-1,185 mm/s) in Group B. In both groups, the implant gradually decelerated because of drag force. With greater distances, the velocity of the DEX implant decreased exponentially to a complete stop at 13.9 mm to 24.7 mm in Group A and at 6.4 mm to 8.0 mm in Group B. Five DEX implants in Group A reached a total distance of more than 15 mm, and their calculated mean velocity at a retinal impact of 15 mm was 408 +/- 145 mm/s (+/- SD, range, 322-667 mm/s), and the consecutive normalized energy was 0.55 +/- 0.44 J/m(2) (+/- SD). In Group B, none of the DEX implants reached a total distance of 6 mm or more. An accidental application at an angle of 30 grade and consecutively reduced distance of approximately 6 mm may result in a mean velocity of 844 and mean normalized energy of 0.15 J/m(2) (SD +/- 0.47) in a water-filled eye. Conclusion: The muzzle velocity of DEX implants is approximately 0.8 m/s and decreases exponentially over distance. The drag over time in vitreous is faster than in water. The calculated retinal impact energy does not reach reported damage levels for direct foreign bodies or other projectiles. RETINA 32: 2133-2140, 2012

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据