期刊
RESPIRATION
卷 81, 期 3, 页码 223-228出版社
KARGER
DOI: 10.1159/000319037
关键词
Shuttle walk; Exercise testing; Reference values
资金
- Fundacao de Amparo Pesquisa do Estado de Sao Paulo (Foundation for the Support of Research in the State of Sao Paulo) [2007/08673-3]
- Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (National Council for Scientific and Technological Development)
Background: Despite widespread use of the incremental shuttle walk distance (ISWD), there are no reference equations for predicting it. Objectives: We aimed to evaluate ISWD in healthy subjects and to establish a reference equation for its prediction. Methods: 131 Brazilian individuals (61 males; 59 +/- 10 years) performed 2 walk tests in a 10-m long corridor. We assessed height, weight, body mass index, forced expiratory volume in 1 s, forced vital capacity and self-reported physical activity. Results: Mean ISWD was greater in males than in females (606 +/- 167 vs. 443 +/- 117 m; p < 0.001). ISWD correlated significantly (p < 0.05) with age (r = -0.51), height (r = 0.54) and weight (r = 0.20). A predictive model including age, height, weight and gender explained 50.3% of the ISWD variance. In an additional group of 20 subjects prospectively studied, the difference between measured and predicted ISWD was not statistically significant (534 +/- 84 vs. 552 +/- 87 m, respectively), representing 97 +/- 12% of the predicted value calculated with our reference equation for ISWD. Conclusions: This reference equation including demographic and anthropomorphic attributes could be useful for interpreting the walking performance of patients with chronic diseases that affect exercise capacity. Copyright (C) 2010 S. Karger AG, Basel
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据