4.2 Article

Estimating Energy Expenditure With the RT3 Triaxial Accelerometer

期刊

RESEARCH QUARTERLY FOR EXERCISE AND SPORT
卷 80, 期 2, 页码 249-256

出版社

AMER ALLIANCE HEALTH PHYS EDUC REC & DANCE
DOI: 10.1080/02701367.2009.10599559

关键词

physical activity; activity counts; motion sensor; body composition

资金

  1. National Institutes of Health

向作者/读者索取更多资源

The RT3 is a relatively new triaxial accelerometer that has replaced the TriTrac. The aim of this study was to validate the RT3 against doubly labeled water (DLW) in a free-living, mixed weight sample of adults. Total energy expenditure (TEE) was measured over a 15-day period using DLW. Activity-related energy expenditure (AEE) was estimated by subtracting resting energy expenditure and thermic effect of feeding from TEE. The RT3 triaxial accelerometer was worn over 14 consecutive days. TEE and AEE were estimated using the RT3 proprietary equation. Thirty-six adults ages 18-56 years (56% women) with an average weight of 7.59 kg (SD = 14.8) completed all measurements. Compared to DLW, the RT3 underestimated TEE by 539 kJ (4%) and AEE by 485 kJ (15%) on average. The RT3 provided a relatively accurate assessment of free-living activity related energy expenditure at the group level and generally underestimated total and activity-related energy expenditure compared to DLW.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据