4.2 Article

Accuracy of inhaled agent usage displays of automated target control anesthesia machines

期刊

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s10877-015-9746-z

关键词

Target control; Automated low flow; Closed loop; Equipment; Anesthesia machine

资金

  1. AbbVie
  2. Acertys
  3. Air Liquide
  4. Allied healthcare
  5. Armstrong Medical
  6. Baxter
  7. Draeger
  8. GE
  9. Hospithera
  10. Heinen und Lowensein
  11. Intersurgical
  12. Maquet
  13. MDMS
  14. MEDEC
  15. Micropore
  16. Molecular
  17. NWS
  18. Philips
  19. Quantum Medical

向作者/读者索取更多资源

Automated low flow anesthesia machines report how much inhaled anesthetic agent has been used for each anesthetic. We compared these reported values with the amount of agent that had disappeared by weighing the vaporizer/injectors before and after each anesthetic. The vaporizers/injectors of the Aisys, Zeus and FLOW-i were weighed with a high precision weighing scale before and after anesthesia with either desflurane in O-2/air or sevoflurane in O-2/N2O. These values were compared with the values reported by the cumulative agent use display tools of the respective anesthesia machines using a linear curve fit. Twenty-five measurements were performed in each group, except for the sevoflurane data with the Aisys that were available from another study (87 pairs). We also determined the amount lost by inserting and removing the vaporizers/injectors or by performing a machine checkout, corrected the measured amounts for these artifacts and repeated the linear fits. The average amount of sevoflurane and desflurane wasted by inserting and removing the cassette for the Aisys, Zeus, and FLOW-i were 0.21, 0.12, and 0.04 mL and 0.12, 0.61, and 1.13 mL liquid agent, respectively. The average amount of sevoflurane and desflurane wasted by the machine checkout with the Aisys, Zeus, and FLOW-i were 1.78, 0.21, and 1.67 mL and 2.39, 0.67, and 4.19 mL, respectively. Performance error of the displayed amount of agent use remained within 10 % of the weighed amount, expect for amounts less than 3 mL sevofurane with the FLOW-i and less than 20 mL desflurane with the Aisys and FLOW-i. Cumulative agent usage displayed by the Aisys, Zeus, and FLOW-i is within 10 % of the measured consumption, except for low consumption cases (< 3 mL sevoflurane, < 20 mL desflurane). The differences may be due to either measurement error or cumulative agent display error. The current results can help the researchers decide whether the displayed amounts are accurate enough for their study purposes. The extent to which these discrepancies differ between different units of the same machine remains unstudied.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据