This work presents an experimental comparison of two algorithms developed in order to maximize the output power from a photovoltaic (PV) system for the same given set of conditions. The maximum power point tracking (MPPT) methods proposed in this study are two extended algorithms: Perturb and Observe and Incremental Conductance. The numerical modelling of the PV system shows the MPPT interest and then the extended MPPT algorithms are highlighted. In this paper, a PV system based on a boost converter as MPPT device is considered. A programmable DC electronic load is fed by two identical PV systems in which the MPPT control converter algorithms are different. This experimental platform operates under the same conditions such as changing solar radiation and cell temperature. The experimental results obtained with a dSPACE controller board show the MPPT energy efficiency of the proposed algorithms. (C) 2010 Elsevier Ltd. All rights reserved.