4.7 Article

CFD based performance analysis of a solar air heater duct provided with artificial roughness

期刊

RENEWABLE ENERGY
卷 34, 期 5, 页码 1285-1291

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.renene.2008.09.015

关键词

Solar air heater; Artificial roughness; CFD; Heat transfer; Friction; Turbulence

向作者/读者索取更多资源

In the present work the performance of a solar air heater duct provided with artificial roughness in the form of thin circular wire in arc shaped geometry has been analysed using Computational Fluid Dynamics (CFD). The effect of arc shaped geometry on heat transfer coefficient, friction factor and performance enhancement was investigated covering the range of roughness parameter (relative roughness height (e/D) from 0.0299 to 0.0426 and relative roughness angle (alpha/90) from 0.333 to 0.666) and working parameter (Reynolds number, Re from 6000 to 18,000 and solar radiation of 1000 W/m2). Different turbulent models have been used for the analysis and their results are compared. Renormalization-group (RNG) k-epsilon model based results have been found in good agreement and accordingly this model is used to predict heat transfer and friction factor in the duct. The overall enhancement ratio has been calculated in order to discuss the overall effect of the roughness and working parameters. A maximum value of overall enhancement ratio has been found to be as 1.7 for the range of parameters investigated. (C) 2008 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据