4.7 Article

Phase-Contrast CT: Qualitative and Quantitative Evaluation of Atherosclerotic Carotid Artery Plaque

期刊

RADIOLOGY
卷 271, 期 3, 页码 870-878

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.14131554

关键词

-

资金

  1. German Academic Foundation (Deutsche Forschungsgemeinschaft, DFG) Cluster of Excellence Munich-Centre for Advanced Photonics (MAP), Munich, Germany
  2. DFG Gottfried Wilhelm Leibniz Program, Bonn, Germany
  3. European Research Council (ERC), Brussels, Belgium [StG 240142]
  4. Program for Education and Science (Forderprogramm fur Forschung und Lehre, FoFoLe) of the Medical Faculty of the Ludwig-Maximilians-University Munich, Munich, Germany

向作者/读者索取更多资源

Purpose: To evaluate the potential of phase-contrast computed tomography (CT) for atherosclerotic plaque imaging in human carotid arteries in an experimental ex vivo study. Materials and Methods: The study was approved by the institutional review board, and informed consent was obtained from the patients' relatives. Seven postmortem human carotid artery specimens were imaged at a laboratory setup by using a conventional x-ray tube and grating interferometer. After histologic processing, phase-contrast imaging and histopathologic data were matched. Characteristics of the necrotic core (NC) covered by a fibrous cap (FC), intraplaque hemorrhage (IPH), and calcifications (CAs) were established, and sensitivity, specificity, and accuracy of phase-contrast CT for plaque detection and the potential for accurate quantification were assessed. The Cohen kappa and Pearson correlation coefficient R were used to determine the agreement between phase-contrast imaging and histopathologic findings for plaque characterization and correlation of quantitative plaque measurements, respectively. A difference with a P value of less than .05 was considered significant. Results: Characteristic criteria were found in all analyzed plaque components. Applying these criteria, phase-contrast CT had a good sensitivity for the detection of the FC and NC, IPH, and CAs (all >80%) and excellent specificity and accuracy (all >90%), with good interreader agreement (kappa >= 0.72, P < .0001). There were excellent correlations for quantitative measurements of FC, NC, and CAs between phase-contrast imaging and histopathologic findings (R >= 0.92). Interreader reproducibility was excellent, with an intraclass correlation coefficient of 0.98 or higher for all measurements. Conclusion: The results of this study indicate that ex vivo phase-contrast CT can help identify and quantify atherosclerotic plaque components, with excellent correlation to histopathologic findings. Although not yet applicable in vivo, phase-contrast CT may become a valuable tool to monitor atherosclerotic disease process noninvasively.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据