4.7 Article

Quantitative Analysis of 1.5-T Whole-Heart Coronary MR Angiograms Obtained with 32-Channel Cardiac Coils: A Comparison with Conventional Quantitative Coronary Angiography

期刊

RADIOLOGY
卷 271, 期 2, 页码 356-364

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.13122491

关键词

-

向作者/读者索取更多资源

Purpose: To develop a method to determine significant stenosis at whole-heart coronary magnetic resonance (MR) angiography and to evaluate the accuracy and reproducibility of this approach. Materials and Methods: The institutional review board approved the study, and all participants provided written informed consent. Sixty-two patients who were suspected of having coronary artery disease (CAD) and were scheduled for conventional coronary angiography were included. Coronary MR angiography was performed by using a 1.5-T imager with 32-channel coils. Luminal narrowing was evaluated with quantitative analysis (QA) of coronary MR angiograms on the basis of the signal intensity profile along the vessel. Percentage stenosis with QA of coronary MR angiograms was calculated as [1 - (SImin/SIref)] Chi 100, where SImin is minimal signal intensity and SIref is corresponding reference signal intensity. Diagnostic performance of QA of coronary MR angiograms for predicting at least a 50% reduction in diameter was evaluated by using quantitative coronary angiography (QCA), with conventional angiography findings serving as the reference standard. Receiver operating characteristic (ROC) analysis, Spearman rank correlation, Bland-Altman analysis, and Cohen k analysis were used. Results: The areas under the ROC curve in a segment-based analysis for detecting significant CAD were 0.96 (95% confidence interval [CI]: 0.94, 0.98) with QA of coronary MR angiograms and 0.93 (95% CI: 0.88, 0.98) with visual assessment. The correlation coefficients between percentage stenosis with QA of coronary MR angiograms and percentage stenosis with QCA were 0.84 (P < .001), 0.80 (P < .001), and 0.66 (P < .001) in the patient-, vessel-, and segment-based analyses, respectively. Conclusion: QA of coronary MR angiograms with use of a signal intensity profile along the vessel permits detection of CAD. This method had a diagnostic performance approximately equal to that of visual analysis of coronary MR angiograms with high inter-and intraobserver reliability, allowing for more objective interpretation of coronary MR angiography findings. (C) RSNA, 2013

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据