4.7 Article

Quantification of Muscle Fat in Patients with Low Back Pain: Comparison of Multi-Echo MR Imaging with Single-Voxel MR Spectroscopy

期刊

RADIOLOGY
卷 266, 期 2, 页码 555-563

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.12120399

关键词

-

资金

  1. Siemens
  2. Toshiba
  3. Carestream
  4. Multiple Grand Rounds

向作者/读者索取更多资源

Purpose: To compare lumbar muscle fat-signal fractions derived from three-dimensional dual gradient-echo magnetic resonance (MR) imaging and multiple gradient-echo MR imaging with fractions from single-voxel MR spectroscopy in patients with low back pain. Materials and Methods: This prospective study had institutional review board approval, and written informed consent was obtained from all study participants. Fifty-six patients (32 women; mean age, 52 years +/- 15 [standard deviation]; age range, 20-79 years) with low back pain underwent standard 1.5-T MR imaging, which was supplemented by dual-echo MR imaging, multi-echo MR imaging, and MR spectroscopy to quantify fatty degeneration of bilateral lumbar multifidus muscles in a region of interest at the intervertebral level of L4 through L5. Fat-signal fractions were determined from signal intensities on fat-and water-only images from both imaging data sets (dual-echo and multi-echo fat-signal fractions without T2* correction) or directly obtained, with additional T2* correction, from multi-echo MR imaging. The results were compared with MR spectroscopic fractions. The Student t test and Bland-Altman plots were used to quantify agreement between fat-signal fractions derived from imaging and from spectroscopy. Results: In total, 102 spectroscopic measurements were obtained bilaterally (46 of 56) or unilaterally (10 of 56). Mean spectroscopic fat-signal fraction was 19.6 +/- 11.4 (range, 5.4-63.5). Correlation between spectroscopic and all imaging-based fat-signal fractions was statistically significant (R-2 = 0.87-0.92; all P < .001). Mean dual-echo fat-signal fractions not corrected for T2* and multi-echo fat-signal fractions corrected for T2* significantly differed from spectroscopic fractions (both P < .01), but mean multi-echo fractions not corrected for T2* did not (P = .11). There was a small measurement bias of 0.5% (95% limits of agreement: 26.0%, 7.2%) compared with spectroscopic fractions. Conclusion: Large-volume image-based (dual-echo and multi-echo MR imaging) and spectroscopic fat-signal fractions agree well, thus allowing fast and accurate quantification of muscle fat content in patients with low back pain. (C)RSNA, 2012

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据