4.7 Article

Diffusion-weighted Endorectal MR Imaging at 3 T for Prostate Cancer: Tumor Detection and Assessment of Aggressiveness

期刊

RADIOLOGY
卷 259, 期 3, 页码 775-784

出版社

RADIOLOGICAL SOC NORTH AMERICA (RSNA)
DOI: 10.1148/radiol.11102066

关键词

-

资金

  1. German Research Foundation [DFG-FR 2891/1-1]

向作者/读者索取更多资源

Purpose: To assess the incremental value of diffusion-weighted (DW) magnetic resonance (MR) imaging over T2-weighted MR imaging at 3 T for prostate cancer detection and to investigate the use of the apparent diffusion coefficient (ADC) to characterize tumor aggressiveness, with whole-mount step-section pathologic analysis as the reference standard. Materials and Methods: The Internal Review Board approved this HIPAA-compliant retrospective study and waived informed consent. Fifty-one patients with prostate cancer (median age, 58 years; range, 46-74 years) underwent T2-weighted MR imaging and DW MR imaging (b values: 0 and 700 sec/mm(2) [n = 20] or 0 and 1000 sec/mm(2) [n = 31]) followed by prostatectomy. The prostate was divided into 12 regions; two readers provided a score for each region according to their level of suspicion for the presence of cancer on a five-point scale, first using T2-weighted MR imaging alone and then using T2-weighted MR imaging and the ADC map in conjunction. Areas under the receiver operating characteristic curve (AUCs) were estimated to evaluate performance. Generalized estimating equations were used to test the ADC difference between benign and malignant prostate regions and the association between ADCs and tumor Gleason scores. Results: For tumor detection, the AUCs for readers 1 and 2 were 0.79 and 0.76, respectively, for T2-weighted MR imaging and 0.79 and 0.78, respectively, for T2-weighted MR imaging plus the ADC map. Mean ADCs for both cancerous and healthy prostatic regions were lower when DW MR imaging was performed with a b value of 1000 sec/mm2 rather than 700 sec/mm2. Regardless of the b value used, there was a significant difference in the mean ADC between malignant and benign prostate regions. A lower mean ADC was significantly associated with a higher tumor Gleason score (mean ADCs of [1.21, 1.10, 0.87, and 0.69] x 10(-3) mm(2)/sec were associated with Gleason score of 3 + 3, 3 + 4, 4 + 3, and 8 or higher, respectively; P = .017). Conclusion: Combined DW and T2-weighted MR imaging had similar performance to T2-weighted MR imaging alone for tumor detection; however, DW MR imaging provided additional quantitative information that significantly correlated with prostate cancer aggressiveness. (C) RSNA, 2011

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据