4.7 Article

Hyperpolarized 3He MR for Sensitive Imaging of Ventilation Function and Treatment Efficiency in Young Cystic Fibrosis Patients with Normal Lung Function

期刊

RADIOLOGY
卷 255, 期 1, 页码 225-232

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.09090039

关键词

-

资金

  1. Vaincre La Mucoviscidose
  2. Hospices Civils de Lyon
  3. European Union Marie Curie Research Training Network PHeLINet [MRTN-CT-2006-036002]
  4. Centre d'Investigation Clinique de Lyon

向作者/读者索取更多资源

Purpose: To assess the sensitivity of hyperpolarized helium 3 (He-3) magnetic resonance (MR) imaging for the detection of peripheral airway obstruction in younger cystic fibrosis (CF) patients showing normal spirometric results (mean forced expiratory volume in 1 second [FEV1], 112% +/- 14.5 [standard deviation]) and to observe the immediate effects of a single chest physical therapy (CPT) session, thereby comparing two image quantification techniques. Materials and Methods: Ten pediatric CF patients (age range, 8-16 years) with normal spirometric results were included in this study after approval from the local research ethics committee. Spirometry followed by proton and hyperpolarized 3 He three-dimensional lung imaging were performed with a 1.5-T MR unit before and after 20 minutes of CPT. The number of ventilation defects per image (VDI) and the ventilated lung fraction (VF), defined as the ratio of ventilated lung volume divided by total lung volume, were quantified. Results: Ventilation defects were found in all patients (mean VDI, 5.1 +/- 1.9; mean global VF, 78.5% +/- 12.3; and mean peripheral VF, 75.5% +/- 17.1) despite normal spirometric results. After CPT, disparate changes in the distribution of ventilation defects were observed but the average VDI and VF did not change significantly (mean VDI, 5.1 +/- 1.1; mean global VF, 83.5% +/- 12.2; and mean peripheral VF, 80.3% +/- 12.2). There was no correlation between FEV1 and VDI (rho = -0.041, P = .863) or global VF (rho = -0.196, P = .408) values but peripheral VF and VDI were correlated (rho = -0.563, P = .011). Conclusion: Although spirometric results indicate normal lung function, the mean VDI in patients (5.1) found in this study is well above the VDI in healthy subjects (1.6) reported in the literature. A single CPT session induces disparate changes in the distribution and extent of ventilation defects. (C) RSNA, 2010

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据