4.7 Article

Middle Ear Cholesteatoma: Non-Echo-planar Diffusion-weighted MR Imaging versus Delayed Gadolinium-enhanced T1-weighted MR Imaging-Value in Detection

期刊

RADIOLOGY
卷 255, 期 3, 页码 866-872

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.10091140

关键词

-

向作者/读者索取更多资源

Purpose: To retrospectively compare non-echo-planar (non-EP) diffusion-weighted (DW) imaging, delayed gadolinium-enhanced T1-weighted magnetic resonance (MR) imaging, and the combination of both techniques in the evaluation of patients with cholesteatoma. Materials and Methods: This institutional review board-approved study, for which the need to obtain informed consent was waived, included 57 patients clinically suspected of having a middle ear cholesteatoma without a history of surgery and 63 patients imaged before second-look surgery. Four blinded radiologists evaluated three sets of MR images: a set of delayed gadolinium-enhanced T1-weighted images, a set of non-EP DW images, and a set of both kinds of images. Overall sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV), as well as intra- and inter-observer agreement, were assessed and compared among methods. To correct for the correlation between different readings, a generalized estimating equations logistic regression model was fitted. Results were compared with surgical results, which were regarded as the standard of reference. Results: Sensitivity, specificity, NPV, and PPV were significantly different between the three methods (P<.005). Sensitivity and specificity, respectively, were 56.7% and 67.6% with the delayed gadolinium-enhanced T1-weighted images and 82.6% and 87.2% with the non-EP DW images. Sensitivity for the combination of both kinds of images was 84.2%, while specificity was 88.2%. The overall PPV was 88.0% for delayed gadolinium-enhanced T1-weighted images, 96.0% for non-EP DW images, and 96.3% for the combination of both kinds of images. The overall NPV was 27.0% for delayed gadolinium-enhanced T1-weighted images, 56.5% for non-EP DW images, and 59.6% for the combination of both kinds of images. Conclusion: MR imaging for detection of middle ear cholesteatoma can be performed by using non-EP DW imaging sequences alone. Use of the non-EP DW imaging sequence combined with a delayed gadolinium-enhanced T1-weighted sequence yielded no significant increases in sensitivity, specificity, NPV, or PPV over the use of the non-EP DW imaging sequence alone. (c) RSNA, 2010

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据