期刊
RADIATION RESEARCH
卷 171, 期 6, 页码 657-663出版社
RADIATION RESEARCH SOC
DOI: 10.1667/RR1371.1
关键词
-
资金
- Comite de Loire-Atlantique de la Ligue Nationale de Lutte Contre le Cancer
- [FP7-HEATH2007-A]
A microdosimetric model that makes it possible to consider the numerous biological and physical parameters of cellular a-particle irradiation by radiolabeled mAbs was developed. It allows for the calculation of single-hit and multi-hit distributions of specific energy within a cell nucleus or a whole cell in any irradiation configuration. Cells are considered either to be isolated or to be packed in a monolayer or a spheroid. The method of calculating energy deposits is analytical and is based on the continuous-slowing-down approximation. A model of cell survival, calculated from the microdosimetric spectra and the microdosimetric radiosensitivity, z(0) was also developed. The algorithm of calculations was validated by comparison with two general Monte Carlo codes: MCNPX and Geant4. Microdosimetric spectra determined by these three codes showed good agreement for numerous geometrical configurations. The analytical method was far more efficient in terms of calculation time: A gain of more than 1000 was observed when using our model compared with Monte Carlo calculations. Good agreements were also observed with previously published results. (C) 2009 by Radiation Research Society
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐