4.2 Article

A CASE STUDY ON THE USE OF SEASONAL CORRECTION FACTORS FOR INDOOR RADON MEASUREMENTS

期刊

RADIATION PROTECTION DOSIMETRY
卷 183, 期 4, 页码 423-431

出版社

OXFORD UNIV PRESS
DOI: 10.1093/rpd/ncy161

关键词

-

资金

  1. Eskisehir Osmangazi University Scientific Research Project [2010/19014]

向作者/读者索取更多资源

Radon concentration measurements were performed in the city Eskisehir, Turkey in order to quantify seasonal variation. Using the assumption that indoor radon concentrations exhibit annual cyclic behavior, Pinels methodology was employed to obtain seasonal correction factors (SCFs). A total of 142 dwellings had radon concentration data for each season that enabled to obtain annual average radon concentrations. Estimated SCFs were applied to each of the 142 dwellings to assess the validity of the factors. The results demonstrate that even in a very small region significant variation in radon concentrations of different dwellings can be observed, and that a good care should be taken in applying SCFs to a short-term radon measurement to obtain average annual radon concentration.