4.2 Article

MOSFET DOSIMETRY MISSION INSIDE THE ISS AS PART OF THE MATROSHKA-R EXPERIMENT

期刊

RADIATION PROTECTION DOSIMETRY
卷 138, 期 4, 页码 295-309

出版社

OXFORD UNIV PRESS
DOI: 10.1093/rpd/ncp265

关键词

-

资金

  1. Canadian Space Agency (CSA) [08/7003491]

向作者/读者索取更多资源

Radiation measurements of surface and deep organ doses were performed aboard the International Space Station, for the period of January 2006 to April 2007, using a MOSFET dosimetry system combined with the Matroshka-R spherical phantom. The averaged internal and surface dose rates are found to be 0.19 and 0.29 mGy d(-1) respectively. The levels of radiation dose to blood-forming organs (BFO) and to surface organs are compared with recommended safe limits. The maximum measured BFO dose has an average dose rate of 0.23 mGy d(-1) (84 mGy y(-1)), corresponding to 44 % of the recommended ommended annual limit of 0.5 Sv, for a space radiation quality factor of 2.6. The annual surface dose is found to he higher at 126 mGy, corresponding to 16 %, of the eye dose limit and to 11 % of the skin dose limit. Doses calculated using the Spenvis software showed deviations of up to 37 % from measurements.