Portable gamma spectrometry with cerium-doped lanthanum bromide scintillators: Suitability assessments for luminescence and electron spin resonance dating applications

期刊

RADIATION MEASUREMENTS
卷 47, 期 1, 页码 6-18

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.radmeas.2011.09.001

关键词

Lanthanum bromide; Sodium iodide; Scintillator detectors; Portable gamma ray spectrometry; Luminescence dating; Electron spin resonance dating

资金

  1. CENIEH
  2. MNHN
  3. Ministerio de Ciencia e Innovacion de Espana
  4. Marie Curie International Reintegration [PIRG08-GA-2010-276810]
  5. [CGL2010-16821]

向作者/读者索取更多资源

Cerium-doped lanthanum bromide (LaBr3:Ce) crystals offer a range of improved scintillation properties over traditional NaI:Tl crystals for in situ gamma spectrometry. At present, however, it remains unclear whether the internal radioactivity of LaBr3:Ce detectors compromises their suitability for low-level activity radioisotope measurements of natural sedimentary deposits, such as those required in luminescence and electron spin resonance (ESR) dating. In this study we investigate the suitability of a commercial LaBr3:Ce detector for measuring individual concentrations of K-40, U-238 and Th-232 using predefined 'energy windows' from gamma ray spectra. Performance tests have been undertaken using reference materials with well-constrained radioisotope concentrations (the Oxford calibration blocks) and compared with results obtained for a NaI:Tl detector of the same geometry. These tests reveal that the LaBr3:Ce detector has a non-negligible intrinsic activity that needs to be accurately quantified prior to measuring any gamma ray spectra in the field. Compared to the NaI:Tl detector, the energy resolution of the LaBr3:Ce detector is improved by a factor of two, or more, for the main indicator isotope photopeaks in the K-40, U-238 and Th-232 decay series. Signal-to-noise ratios for the LaBr3:Ce detector show a 25-35% improvement over those of the NaI:Tl detector. In addition, the LaBr3:Ce detector is characterised by suitable energy linearity over the full spectral range of interest for the K-40, U-238 and Th-232 decay series. Replicate gamma ray measurements made with the LaBr3:Ce and NaI:Tl detectors for 20 natural sedimentary samples from the Lower Tejo River basin, Portugal, and the Duero River basin, Spain, yield consistent radioisotope concentrations and gamma dose rate estimates. These results are encouraging and suggest that LaBr3:Ce detectors can provide suitable estimates of individual radioisotope concentrations in low-level activity (0.5-1.5 Gy/ka) environments, providing that their intrinsic activity is adequately measured and subtracted from field spectra. Our comparison also reveals that subtraction of the intrinsic activity from LaBr3:Ce spectra produces a significant reduction in the precision with which radionuclide concentrations can be determined using the 'energy windows' approach. This shortcoming necessitates longer counting times in natural sedimentary environments and overshadows the practical advantages that LaBr3:Ce detectors might otherwise offer for luminescence and ESR dating applications. (c) 2011 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据