期刊
RADIATION MEASUREMENTS
卷 46, 期 10, 页码 1168-1172出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.radmeas.2011.06.075
关键词
Radon mapping; Seasonal patterns; Regional variation; Fourier decomposition; Correction factors
Radon levels measured for any duration less than one year are subject to seasonal variation. Such radon measurements must therefore be adjusted using an appropriate seasonal correction factor in order to estimate an annual average radon level. Radon mapping has shown that radon concentrations vary between regions within a country but there has been little work examining regional variation in the seasonality of radon levels. This paper investigates this regional variation in indoor radon seasonality in Ireland. Mean regional seasonal correction factors are estimated through Fourier decomposition and we find that there is significant regional variation in the computed seasonal correction factors. We conclude that the use of one national set of mean seasonal correction factors may not be appropriate in all countries. (C) 2011 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐