4.7 Article

Evidence for bias in C/N, δ13C and δ15N values of bulk organic matter, and on environmental interpretation, from a lake sedimentary sequence by pre-analysis acid treatment methods

期刊

QUATERNARY SCIENCE REVIEWS
卷 30, 期 21-22, 页码 3076-3087

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.quascirev.2011.07.003

关键词

C/N ratios; delta C-13; delta N-15; Organic matter; Pre-analysis acid treatment methods; Environmental interpretation; Palaeoclimate

资金

  1. NERC [NE/F007264/1, IP/1165/0510, 1423.1009]
  2. NERC [nigl010001] Funding Source: UKRI
  3. Natural Environment Research Council [nigl010001] Funding Source: researchfish

向作者/读者索取更多资源

There is a known bias in C/N, delta C-13 and delta N-15 values of organic matter (OM) due to pre-analysis acid treatment methods. We report here, for the first time, the results of a pre-analysis acid treatment method comparison of measured C/N, delta C-13 and delta N-15 values in bulk OM from a sedimentary sequence of samples to illustrate this bias. Here we show that acid treatment significantly reduces the accuracy (between method biases) and precision (within method bias) of C/N, delta C-13 and delta N-15 values of OM, suggesting a differential response of sample OM between methods and sample horizons, and in some cases inefficient removal of inorganic carbon. We show that different methods can significantly influence environmental interpretation in some of our sample horizons (i.e. interpretation of aquatic vs. terrestrial OM source; C-3 VS. C-4 vegetation). Specifically, there are unpredictable and non-linear differences between methods for C/N values in the range of similar to 1-100; delta C-13 values in the range of 0.2-6.8 parts per thousand and; delta N-15 values in the range of 0.3-0.7 parts per thousand, Importantly, these ranges are mostly much greater than the instrument precision (defined as the standard deviation of replicate analysis of standard reference materials; for this study, +/- 0.5 for C/N values, +/- 0.1 parts per thousand for delta C-13 values and; +/- 0.1 parts per thousand for delta N-15). The accuracy and precision of measured C/N, delta C-13 and delta N-15 values of bulk OM is not just dependent upon environmental variability, but on acid pre-treatment, residual inorganic carbon and organic matter state and composition. Collectively, this makes the correlation between samples prepared in different ways, including those from down-core reconstructions, highly questionable. (C) 2011 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据