4.5 Article

Modification of the Epworth Sleepiness Scale in Central China

期刊

QUALITY OF LIFE RESEARCH
卷 20, 期 10, 页码 1721-1726

出版社

SPRINGER
DOI: 10.1007/s11136-011-9898-3

关键词

Epworth Sleepiness Scale; Excessive daytime sleepiness; Sleep-disordered breathing

资金

  1. Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry

向作者/读者索取更多资源

The well-known excessive daytime sleepiness (EDS) assessment, Epworth Sleepiness Scale (ESS), is not consistently qualified for patients with diverse living habits. This study is aimed to build a modified ESS (mESS) and then to verify its feasibility in the assessment of EDS for patients with suspected sleep-disordered breathing (SDB) in central China. A Ten-item Sleepiness Questionnaire (10-ISQ) was built by adding two backup items to the original ESS. Then the 10-ISQ was administered to 122 patients in central China with suspected SDB [among them, 119 cases met the minimal diagnostic criteria for obstructive sleep apnea by sleep study, e.g., apnea and hypopnea index (AHI) a parts per thousand yen 5 h(-1)] and 117 healthy central Chinese volunteers without SDB. Multivariate exploratory techniques were used for item validation. The unreliable item in the original ESS was replaced by the eligible backup item, thus a modified ESS (mESS) was built, and then verified. Item 8 proved to be the only unreliable item in central Chinese patients, with the least factor loading on the main factor and the lowest item-total correlation both in the 10-ISQ and in the original ESS, deletion of it would increase the Cronbach's alpha (from 0.86 to 0.87 in the 10-ISQ; from 0.83 to 0.85 in the original ESS). The mESS was subsequently built by replacing item 8 in the original ESS with item 10 in the 10-ISQ. Verification with patients' responses revealed that the mESS was a single-factor questionnaire with good internal consistency (Cronbach's alpha = 0.86). The sum score of the mESS not only correlated with AHI (P < 0.01) but was also able to discriminate the severity of obstructive apnea (P < 0.01). Nasal CPAP treatment for severe OSA reduced the score significantly (P < 0.001). The performance of the mESS was poor in evaluating normal subjects. The mESS improves the validity of ESS for our patients. Therefore, it is justified to use it instead of the original one in assessment of EDS for patients with SDB in central China.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据