4.8 Article

Topographical and electrochemical nanoscale imaging of living cells using voltage-switching mode scanning electrochemical microscopy

出版社

NATL ACAD SCIENCES
DOI: 10.1073/pnas.1203570109

关键词

high-resolution imaging; living cell imaging; noninvasive; constant-distance mode

资金

  1. Japan Society for the Promotion of Science (JSPS) [22245011]
  2. Engineering and Physical Sciences Research Council
  3. Chemical and Biological Program of the National Measurement System of the UK Department of Business, Innovation, and Skills
  4. JSPS Postdoctoral Fellowships for Research Abroad
  5. European Research Council [ERC-2009-AdG2471143-QUANTIF]
  6. Biotechnology and Biological Sciences Research Council [BB/D020816/1, BB/D020875/1] Funding Source: researchfish
  7. Engineering and Physical Sciences Research Council [EP/I007482/1] Funding Source: researchfish
  8. BBSRC [BB/D020875/1, BB/D020816/1] Funding Source: UKRI
  9. EPSRC [EP/I007482/1] Funding Source: UKRI
  10. Grants-in-Aid for Scientific Research [24710140, 22245011] Funding Source: KAKEN

向作者/读者索取更多资源

We describe voltage-switching mode scanning electrochemical microscopy (VSM-SECM), in which a single SECM tip electrode was used to acquire high-quality topographical and electrochemical images of living cells simultaneously. This was achieved by switching the applied voltage so as to change the faradaic current from a hindered diffusion feedback signal (for distance control and topographical imaging) to the electrochemical flux measurement of interest. This imaging method is robust, and a single nanoscale SECM electrode, which is simple to produce, is used for both topography and activity measurements. In order to minimize the delay at voltage switching, we used pyrolytic carbon nanoelectrodes with 6.5-100 nm radii that rapidly reached a steady-state current, typically in less than 20 ms for the largest electrodes and faster for smaller electrodes. In addition, these carbon nanoelectrodes are suitable for convoluted cell topography imaging because the RG value (ratio of overall probe diameter to active electrode diameter) is typically in the range of 1.5-3.0. We first evaluated the resolution of constant-current mode topography imaging using carbon nanoelectrodes. Next, we performed VSM-SECM measurements to visualize membrane proteins on A431 cells and to detect neurotransmitters from a PC12 cells. We also combined VSM-SECM with surface confocal microscopy to allow simultaneous fluorescence and topographical imaging. VSM-SECM opens up new opportunities in nanoscale chemical mapping at interfaces, and should find wide application in the physical and biological sciences.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据