4.1 Article

Are CRT upgrade procedures more complex and associated with more complications than de novo CRT implantations? A single centre experience

期刊

NETHERLANDS HEART JOURNAL
卷 24, 期 1, 页码 75-81

出版社

BOHN STAFLEU VAN LOGHUM BV
DOI: 10.1007/s12471-015-0771-9

关键词

CRT; Upgrade; Complication

向作者/读者索取更多资源

Objective The objective of the study was to examine whether cardiac resynchronisation therapy upgrade procedures are more complex and associated with more complications than de novo implantations. Method We retrospectively compared 134 upgrade procedures performed between 2006-2012 with a random, equally sized, sample of de novo CRT device implantations in the same period. Procedural data and the occurrence of periprocedural (<= 30 days) and long-term device-related (<= 1 year) complications were analysed. Complications with consequences were defined as those in need of adjustment of standard care. Results Median time to upgrade was 57 (31-115) months. There were no significant differences in procedure duration, radiation time or total hospitalisation between upgrades and de novo implantations. Perioperative complications occurred in 6.7 % of upgrade patients and in 9.0 % of de novo patients. The most frequently seen complications were phrenic nerve stimulation, coronary sinus dissection and pocket haematoma. Procedure success was comparable (upgrade: 98.5 % versus de novo: 96.3 %). A total of 236 patients completed 1 year of follow-up. Ten (4.2 %) patients had a long-term device-related complication with consequences including phrenic nerve stimulation, lead dislodgement/dysfunction, and infection (upgrade: 3.5 % versus de novo: 4.9 %). Conclusion Upgrade procedures are not more complex nor associated with more complications than de novo CRT implantations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据