期刊
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY
卷 226, 期 A5, 页码 682-693出版社
SAGE PUBLICATIONS LTD
DOI: 10.1177/0957650912444689
关键词
Closed cycles; carbon dioxide; hydrocarbons; Brayton cycles; condensation cycles; real gas effects; PRSV; Wong-Sandler; critical point of mixtures
Closed Brayton gas and supercritical cycles operating with mixtures of carbon dioxide and hydrocarbons, in particular mixture with a low content (5-15%) of benzene, were studied. Totally, supercritical cycles and condensation cycles were looked at and a comparison was made with pure carbon dioxide cycles with a minimal temperature around 40-50 degrees C (typical minimum temperatures of air cooled radiators). First and second law cycle efficiencies were considered and analysed. Critical point calculations of several mixtures were performed by means of an accurate model for the thermodynamic properties and compared with experimental data from literature. For the cycle calculations, a simpler model with classical mixing rules was used because the results were in sufficient agreement. The cycles operating with mixtures showed lower maximum pressures and higher cycle efficiencies compared to the pure carbon dioxide cycles. Taken into account, the high global warming potential of fluorinated fluids and the high flammability and high volume expansion ratios of comparable Rankine toluene cycles, mixtures of carbon dioxides and hydrocarbons exposed promising features.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐