4.6 Article

Phosphor thermometry: A comparison of the luminescence lifetime and the intensity ratio approach

期刊

PROCEEDINGS OF THE COMBUSTION INSTITUTE
卷 34, 期 -, 页码 3611-3618

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.proci.2012.06.084

关键词

Thermographic phosphors; Phosphor thermometry; Surface temperature

资金

  1. DFG (Deutsche Forschungsgemeinschaft) [DR 374/9-1, EXC 259]

向作者/读者索取更多资源

In the context of phosphor thermometry, the most common measurement strategies, namely the lifetime and the intensity ratio approach, have been compared. Using the phosphor Mg4FGeO6:Mn and the identical experimental setup, both techniques have been characterized in terms of precision and accuracy. Therefore, two-dimensional calibration measurements have been performed to evaluate temperature-lifetime and temperature-ratio characteristics as well as shot-to-shot and pixel-to-pixel standard deviations. In a second experiment, different parameters were varied at constant temperatures to quantify the accuracy of both measurement strategies. Finally, both methods were compared monitoring a spatial temperature gradient. (C) 2012 Published by Elsevier Inc. on behalf of The Combustion Institute.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据