4.7 Article

Heat transfer characteristics of fluidized bed heat exchanger in a 300 MW CFB boiler

期刊

POWDER TECHNOLOGY
卷 222, 期 -, 页码 1-7

出版社

ELSEVIER
DOI: 10.1016/j.powtec.2012.01.017

关键词

Circulating fluidized bed (CFB); Fluidized bed heat exchanger (FBHE); Solids flow; Solids temperature; Heat transfer coefficient

向作者/读者索取更多资源

In order to investigate the heat transfer characteristics of fluidized bed heat exchanger (FBHE), a series of experiments was carried out in a commercial 300 MW circulating fluidized bed (CFB) boiler with FBHE. The parameters of steam, solids and air in FBHE were measured at different boiler loads, based on which the absorbed heat and heat transfer coefficient were calculated. Further study indicates that when the calculated results are applied to the design of large-scale CFB boilers, the bed side heat transfer coefficient in FBHE can be simplified as the function of solids temperature and flow. Therefore, the empirical model of heat transfer coefficient at bed side is put forward. The deviation between calculated results and measured values is acceptable in engineering application. This model provides strong support for the FBHE design in 600 MW supercritical CFB boilers. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据