4.5 Article

Further study on the flammability of polyurea: the effect of intumescent coating and additive flame retardants

期刊

POLYMERS FOR ADVANCED TECHNOLOGIES
卷 22, 期 8, 页码 1297-1304

出版社

WILEY-BLACKWELL
DOI: 10.1002/pat.1963

关键词

polyurea; flame retardancy; cone calorimetry

资金

  1. US Air Force [FA8650-07-1-5901]

向作者/读者索取更多资源

A series of polyurea (PU) samples were prepared and coated with varying thicknesses of commercially available solvent and water-based intumescent paints. Another series of PU composite samples, containing different types of flame retardant additives, were prepared and coated with the intumescent paints. The fire behavior of the samples was investigated by subjecting the samples to the heat flux of the cone calorimeter. The data indicate that the intumescent coat is very effective in imparting flame retardancy to the samples. Combining the flame retardant additives with the coating has no additional effect. Copyright (C) 2011 John Wiley & Sons, Ltd.