4.6 Article

Can smartphone wireless ECGs be used to accurately assess ECG intervals in pediatrics? A comparison of mobile health monitoring to standard 12-lead ECG

期刊

PLOS ONE
卷 13, 期 9, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0204403

关键词

-

资金

  1. AliveCor, Inc.

向作者/读者索取更多资源

Background Arrhythmias in children are often paroxysmal, complicating the ability to capture the abnormal rhythm on routine ECG during an outpatient visit. The Alivecor Kardia Mobile (KM) device is a wireless mobile health (mHealth) device that generates a single lead ECG tracing with a FDA-approved algorithm for detection of atrial fibrillation in adults. Objective The goal of this study is to assess the accuracy of interval measurements on KM tracings by directly comparing to standard 12-lead ECGs in pediatric patients. Methods This single center, prospective study enrolled pediatric outpatients, age <18 years presenting for cardiology clinic visits, into 3 groups based on age: 0-5 years, 6-10 years, and 11-18 years. Patients were excluded if 12-lead ECG was not ordered during the visit. Each enrolled subject underwent standard 12-lead ECG followed by 30-second KM tracing. ECG parameters were batch read by 2 blinded pediatric electrophysiologists. Results Thirty patients were recruited with 10 patients/group. Structural heart disease and/or conduction abnormality was present in 20 patients (67%). Majority of tracings (27/30, 90%) were of diagnostic quality on first attempt. Overall, the Delta PR was 15.2 +/- 10.8ms (r = 0.86), Delta QRS was 9.6 +/- 8ms (r = 0.86), and Delta QTc was 15.6 +/- 12.7ms (r = 0.83). There were 9 patients with Delta QTc measurements >20ms with 4/9 (44%) having a conduction disorder and 2/9 (22%) having marked sinus arrhythmia. Bland-Altman method of agreement demonstrated strong agreement for QRSd and QTc. The AF algorithm reported 4/30 (13%) false positive possible AF diagnoses (rhythm over-read on KM demonstrated n = 3 marked sinus arrhythmia, n = 1 sinus rhythm with aberrated PACs) resulting in a specificity of 87%. Conclusion The Alivecor Kardia device produces accurate single lead ECG tracings in both healthy children and children with cardiac disease or rhythm abnormalities across the pediatric spectrum. This mHealth application provides an accurate, non-invasive, real-time approach for ambulatory ECG monitoring in children and adolescents.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据