4.6 Article

Evaluation of the Double Agar Gel Immunodiffusion Test and of the Enzyme-Linked Immunosorbent Assay in the Diagnosis and Follow-Up of Patients with Chronic Pulmonary Aspergillosis

期刊

PLOS ONE
卷 10, 期 8, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0134841

关键词

-

资金

  1. Coordenation for the Improvement of Higher Level Personnel - CAPES

向作者/读者索取更多资源

The diagnosis of chronic pulmonary aspergillosis (CPA) depends on the radiologic image and the identification of specific antibodies. The present study aimed to evaluate accuracy parameters of enzyme-linked immunosorbent assay (ELISA) and of the determination of serum galactomannan level in the diagnosis of patients with CPA, comparing these results with the double agar gel immunodiffusion (DID) test. In addition, the prevalence of cross-reactivity and the serological progression after treatment were evaluated by comparing DID and ELISA. Six study groups were formed: G1:22 patients with CPA, 17 of whom had Aspergillus fungus ball, one chronic cavitary pulmonary aspergillosis (CCPA) and four chronic fibrosing pulmonary aspergillosis (CFPA); G2:28 patients with pulmonary tuberculosis (TB); G3:23 patients with histoplasmosis (HST); G4:50 patients with paracoccidioidomycosis (PCM); G5:20 patients with cryptococcosis (CRC); and G6:200 healthy controls. Serum antibodies were measured by DID and ELISA, with two antigen preparations-Aspergillus fumigatus (DID1, ELISA(1)) and a pool of A. fumigatus, A. flavus and A. niger antigens (DID2, ELISA(2)). The Platelia Aspergillus Enzyme Immunoassay (EIA) kit was used to measure galactomannan. The cut-off points of ELISA were determined for each antigen preparation and for the 95% and 99% confidence intervals. Despite the low sensitivity, DID was the technique of choice due to its specificity, positive and negative predictive values and positive likelihood ratio-especially with the antigen pool and due to the low frequency of cross-reactivity. ELISA(1) and a 0.090 cut-off showed high sensitivity, specificity and negative predictive value, but a high frequency of cross-reactivity with CRC. The best degree of agreement was observed between ELISA(1) and ELISA(2). The detection of serum galactomannan showed high sensitivity, comparable to ELISA(2). The immunodiffusion test showed an excellent relationship with the progression after treatment, which made it the reaction of choice for patient follow-up.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据