4.6 Article

Total Aortic Arch Replacement: Superior Ventriculo-Arterial Coupling with Decellularized Allografts Compared with Conventional Prostheses

期刊

PLOS ONE
卷 9, 期 7, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0103588

关键词

-

资金

  1. Land Baden-Wurttemberg, Germany
  2. Medical Faculty of the University of Heidelberg, Germany
  3. Hungarian Academy of Sciences
  4. Hungarian Research Fund [OTKA 105555]
  5. National Development Agency of Hungary [TAMOP-4.2.2-08/1/KMR-2008-004, TAMOP-4.2.2/B-10/1-2010-0013]

向作者/读者索取更多资源

Background: To date, no experimental or clinical study provides detailed analysis of vascular impedance changes after total aortic arch replacement. This study investigated ventriculoarterial coupling and vascular impedance after replacement of the aortic arch with conventional prostheses vs. decellularized allografts. Methods: After preparing decellularized aortic arch allografts, their mechanical, histological and biochemical properties were evaluated and compared to native aortic arches and conventional prostheses in vitro. In open-chest dogs, total aortic arch replacement was performed with conventional prostheses and compared to decellularized allografts (n = 5/group). Aortic flow and pressure were recorded continuously, left ventricular pressure-volume relations were measured by using a pressure-conductance catheter. From the hemodynamic variables end-systolic elastance (Ees), arterial elastance (Ea) and ventriculoarterial coupling were calculated. Characteristic impedance (Z) was assessed by Fourier analysis. Results: While Ees did not differ between the groups and over time (4.1 +/- 1.19 vs. 4.58 +/- 1.39 mmHg/mL and 3.21 +/- 0.97 vs. 3.96 +/- 1.16 mmHg/mL), Ea showed a higher increase in the prosthesis group (4.01 +/- 0.67 vs. 6.18 +/- 0.20 mmHg/mL, P<0.05) in comparison to decellularized allografts (5.03 +/- 0.35 vs. 5.99 +/- 1.09 mmHg/mL). This led to impaired ventriculoarterial coupling in the prosthesis group, while it remained unchanged in the allograft group (62.5 +/- 50.9 vs. 3.9 +/- 23.4%). Z showed a strong increasing tendency in the prosthesis group and it was markedly higher after replacement when compared to decellularized allografts (44.6 +/- 8.3dyn.sec.cm(-5) vs. 32.4 +/- 2.0dyn.sec.cm(-5), P<0.05). Conclusions: Total aortic arch replacement leads to contractility-afterload mismatch by means of increased impedance and invert ventriculoarterial coupling ratio after implantation of conventional prostheses. Implantation of decellularized allografts preserves vascular impedance thereby improving ventriculoarterial mechanoenergetics after aortic arch replacement.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据