Objective Assessment of Fall Risk in Parkinson's Disease Using a Body-Fixed Sensor Worn for 3 Days

期刊

PLOS ONE
卷 9, 期 5, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0096675

关键词

-

资金

  1. European Commission [288878]
  2. Michael J. Fox Foundation for Parkinson's Research
  3. Israel Science Foundation
  4. NIH/NIA [5R21AG034227]

向作者/读者索取更多资源

Background: Patients with Parkinson's disease (PD) suffer from a high fall risk. Previous approaches for evaluating fall risk are based on self-report or testing at a given time point and may, therefore, be insufficient to optimally capture fall risk. We tested, for the first time, whether metrics derived from 3 day continuous recordings are associated with fall risk in PD. Methods and Materials: 107 patients (Hoehn & Yahr Stage: 2.6 +/- 0.7) wore a small, body-fixed sensor (3D accelerometer) on lower back for 3 days. Walking quantity (e. g., steps per 3-days) and quality (e. g., frequency-derived measures of gait variability) were determined. Subjects were classified as fallers or non-fallers based on fall history. Subjects were also followed for one year to evaluate predictors of the transition from non-faller to faller. Results: The 3 day acceleration derived measures were significantly different in fallers and non-fallers and were significantly correlated with previously validated measures of fall risk. Walking quantity was similar in the two groups. In contrast, the fallers walked with higher step-to-step variability, e. g., anterior-posterior width of the dominant frequency was larger (p = 0.012) in the fallers (0.78 +/- 0.17 Hz) compared to the non-fallers (0.71 +/- 0.07 Hz). Among subjects who reported no falls in the year prior to testing, sensor-derived measures predicted the time to first fall (p = 0.0034), whereas many traditional measures did not. Cox regression analysis showed that anterior-posterior width was significantly (p = 0.0039) associated with time to fall during the follow-up period, even after adjusting for traditional measures. Conclusions/Significance: These findings indicate that a body-fixed sensor worn continuously can evaluate fall risk in PD. This sensor-based approach was able to identify transition from non-faller to faller, whereas many traditional metrics were not successful. This approach may facilitate earlier detection of fall risk and may in the future, help reduce high costs associated with falls.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据