4.6 Article

Imperfect Implementation of an Early Warning Scoring System in a Danish Teaching Hospital: A Cross-Sectional Study

期刊

PLOS ONE
卷 8, 期 7, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0070068

关键词

-

资金

  1. Danish Society for Patient Safety

向作者/读者索取更多资源

Background: In 2007, the initiation of a patient safety campaign led to the introduction of Ward Observational Charts (WOC) and Medical Early Warning Score (MEWS) at Naestved Regional Hospital. This included systematic measuring of vital signs of all patients in order to prevent patient deterioration and assure timely and correct initiation of treatment. The aim of this study was to assess to what degree WOC guidelines being followed by ward staff. Design and Setting: A 7-day prospective, observational, randomised, cross-sectional, point prevalence study of WOC guideline compliance in hospitalised patients on twelve wards at Naestved Hospital. Results: The study included 132 patients. Of these, 58% had been observed and managed correctly according to WOC guidelines. 77% had all MEWS elements recorded by staff. One patient had no MEWS elements recorded. Only 38% of patients with abnormal MEWS were correctly escalated by nursing staff. Staff was aware of the abnormal MEWS observed by investigator in 60% of the patients. Each element of WOC was on average recorded by staff in 90% of the patients. Conclusion: At the time of our study, the long-term implementation of WOC guidelines has not been completed satisfactorily. The lacking component in the implementation of MEWS and WOC is the documentation of action taken upon finding an abnormal value. Unsuccessful implementation could result in incorrect results from evaluation of an early warning system. We suggest a redesign of the training programme to educate staff in recognising and caring for critically ill patients at Naestved Hospital.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据