4.5 Article

Association of placental perfusion, as assessed by magnetic resonance imaging and uterine artery Doppler ultrasound, and its relationship to pregnancy outcome

期刊

PLACENTA
卷 34, 期 10, 页码 885-891

出版社

W B SAUNDERS CO LTD
DOI: 10.1016/j.placenta.2013.07.006

关键词

FAIR; IVIM; Magnetic resonance imaging; Placenta; Uterine artery Doppler; Perfusion; Small for gestational age; Fetal growth restriction

资金

  1. Fetal Medicine Foundation (UK) [1037116]

向作者/读者索取更多资源

Purpose: To investigate (a) if placental perfusion in the second trimester of pregnancy, measured by two non-invasive magnetic resonance imaging (MRI) techniques, is related to impedance to flow in the uterine arteries, as assessed by Doppler ultrasound; and (b) if these measures are associated with future gestational outcome. Methods: In 37 singleton pregnancies at 24-29 weeks' gestation, uterine artery pulsatility index (PI) was measured by Doppler ultrasound and placental perfusion was measured by Arterial Spin Labelling (flow-sensitive alternating inversion recovery (FAIR)) and intravoxel incoherent motion (IVIM) echo-planar imaging at 1.5 T in basal, central and placental regions of interest. The values were compared between those delivering small for gestational age (SGA) and appropriate for gestational age (AGA) neonates. Results: In 23 pregnancies that resulted in delivery of SGA neonates, compared to the 14 with AGA neonates, the median basal FAIR measure was significantly lower (923.0 vs. 2359.0 arbitrary units; p = 0.003) as were IVIM measures of perfusing fraction (f) in basal, central and whole-placental regions (37.8 vs. 40.7%; p = 0.046; 24.3 vs. 35.1%; p = 0.014 and 27.9% vs. 36.2%; p = 0.001, respectively). In the SGA group, the median uterine artery PI was increased (1.96 vs. 1.03; p = 0.001). There were significant associations between uterine artery PI and placental perfusion assessed by both FAIR and IVIM. Conclusion: Pregnancies that result in SGA neonates exhibited reduced placental perfusion as assessed by MRI during the second trimester. This measurement was found to be strongly associated with impedance to flow in the uterine arteries. We suggest that FAIR or IVIM MRI examinations may be used to directly and non-invasively determine placental perfusion, and that the measured values are strong indicators of future gestational outcome. (C) 2013 Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据