4.4 Article

Reliability of a test measuring transversus abdominis muscle recruitment with a pressure biofeedback unit

期刊

PHYSIOTHERAPY
卷 95, 期 1, 页码 8-14

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.physio.2008.10.003

关键词

Low back pain; Pressure biofeedback; Transversus abdominis; Reliability

资金

  1. German Federal Ministry of Health and Social Security [124-43164-1/527]

向作者/读者索取更多资源

Background There are indications that segmental stabilising exercises (SSEs) are effective in the treatment of low back pain. The evaluation Of Successful training in SSE performance in patients requires a reliable Outcome measure. The PRONE test gives an indication of the activity of the transversus abdominis Muscle. Performed in prone lying using a pressure biofeedback unit, it has been used as an aid to training and to assess the subject's ability to perform SSEs correctly. Objectives To evaluate inter-observer and test-retest reliability of the PRONE test. Design Repeated measures by three observers oil 2 days. Setting Department of Physical Medicine and Rehabilitation. Ludwig-Maximilian University, Munich, Germany. Participants Forty nurses (39 females and one male), aged between 24 and 62 years, with at least one episode of low back pain. Main outcome measures During the test. movement of the abdominal wall was monitored by measuring a change ill pressure during Muscle contraction termed 'abdominal hollowing'. Defined observation and palpation criteria were verified by the observers to ensure correct execution of the test. Methods Participants were tested oil two separate days. On the first day. Observer A performed two similar test sets. each with four exercises. On the second test day, Observers B and C conducted one test set each. Results This Study found ail intra-class correlation coefficient (ICC) of 0.47 [95% confidence interval (CI) 0.20 to 0.67] for inter-observer reliability, and an ICC of 0.81 (95% CI 0.67 to 0.90) for test-retest reliability. Kappa values and the limits of agreement Were also calculated with similar results. Conclusions For this Subject group, the PRONE test had relatively low inter-observer reliability but. as may be expected, higher test-retest reliability. It is suggested that by providing Visual feedback. the PRONE test may enhance patients' insight into their deep abdominal Muscle recruitment and thereby increase their motivation to exercise. (C) 2008 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据