4.6 Article

Diagnostic Accuracy of Fall Risk Assessment Tools in People With Diabetic Peripheral Neuropathy

期刊

PHYSICAL THERAPY
卷 92, 期 11, 页码 1461-1470

出版社

OXFORD UNIV PRESS INC
DOI: 10.2522/ptj.20120070

关键词

-

资金

  1. University of Kansas Medical Center General Clinical Research Center [M01 RR 02394]
  2. National Center for Research Resources/National Institutes of Health, Frontiers: The Heartland Institute for Clinical and Translational Research (University of Kansas Medical Center's CTSA [UL1RR033179]
  3. Kansas Partners in Progress

向作者/读者索取更多资源

Background. Diabetic peripheral neuropathy affects nearly half of individuals with diabetes and leads to increased fall risk. Evidence addressing fall risk assessment for these individuals is lacking. Objective. The purpose of this study was to identify which of 4 functional mobility fall risk assessment tools best discriminates, in people with diabetic peripheral neuropathy, between recurrent fallers and those who are not recurrent fallers. Design. A cross-sectional study was conducted. Setting. The study was conducted in a medical research university setting. Participants. The participants were a convenience sample of 36 individuals between 40 and 65 years of age with diabetic peripheral neuropathy. Measurements. Fall history was assessed retrospectively and was the criterion standard. Fall risk was assessed using the Functional Reach Test, the Timed Up & Go Test, the Berg Balance Scale, and the Dynamic Gait Index. Sensitivity, specificity, positive and negative likelihood ratios, and overall diagnostic accuracy were calculated for each fall risk assessment tool. Receiver operating characteristic curves were used to estimate modified cutoff scores for each fall risk assessment tool; indexes then were recalculated. Results. Ten of the 36 participants were classified as recurrent fallers. When traditional cutoff scores were used, the Dynamic Gait Index and Functional Reach Test demonstrated the highest sensitivity at only 30%; the Dynamic Gait Index also demonstrated the highest overall diagnostic accuracy. When modified cutoff scores were used, all tools demonstrated improved sensitivity (80% or 90%). Overall diagnostic accuracy improved for all tests except the Functional Reach Test; the Timed Up & Go Test demonstrated the highest diagnostic accuracy at 88.9%. Limitations. The small sample size and retrospective fall history assessment were limitations of the study. Conclusions. Modified cutoff scores improved diagnostic accuracy for 3 of 4 fall risk assessment tools when testing people with diabetic peripheral neuropathy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据