4.7 Article

Measurement of the B- lifetime using a simulation free approach for trigger bias correction

期刊

PHYSICAL REVIEW D
卷 83, 期 3, 页码 -

出版社

AMER PHYSICAL SOC
DOI: 10.1103/PhysRevD.83.032008

关键词

-

资金

  1. U.S. Department of Energy
  2. National Science Foundation
  3. Italian Istituto Nazionale di Fisica Nucleare
  4. Ministry of Education, Culture, Sports, Science, and Technology of Japan
  5. Natural Sciences and Engineering Research Council of Canada
  6. National Science Council of the Republic of China
  7. Swiss National Science Foundation
  8. A.P. Sloan Foundation
  9. Bundesministerium fur Bildung und Forschung, Germany
  10. National Research Foundation of Korea
  11. Science and Technology Facilities Council
  12. Royal Society, United Kingdom
  13. Institut National de Physique Nucleaire et Physique des Particules/CNRS
  14. Russian Foundation for Basic Research
  15. Ministerio de Ciencia e Innovacion, Spain
  16. Slovak RD Agency
  17. Academy of Finland
  18. Science and Technology Facilities Council [PP/E000444/1, ST/H001026/2, ST/H001069/1, ST/H001026/1, ST/H001077/1] Funding Source: researchfish
  19. Grants-in-Aid for Scientific Research [18071002] Funding Source: KAKEN
  20. STFC [ST/H001077/1, ST/H001026/2, ST/H001026/1, ST/H001069/1] Funding Source: UKRI

向作者/读者索取更多资源

The collection of a large number of B-hadron decays to hadronic final states at the CDF II Detector is possible due to the presence of a trigger that selects events based on track impact parameters. However, the nature of the selection requirements of the trigger introduces a large bias in the observed proper-decay-time distribution. A lifetime measurement must correct for this bias, and the conventional approach has been to use a Monte Carlo simulation. The leading sources of systematic uncertainty in the conventional approach are due to differences between the data and the Monte Carlo simulation. In this paper, we present an analytic method for bias correction without using simulation, thereby removing any uncertainty due to the differences between data and simulation. This method is presented in the form of a measurement of the lifetime of the B- using the mode B- -> D-0 pi(-). The B- lifetime is measured as tau(-)(B) = 1.663 +/- 0.023 +/- 0.015 ps, where the first uncertainty is statistical and the second systematic. This new method results in a smaller systematic uncertainty in comparison to methods that use simulation to correct for the trigger bias.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据