4.7 Article

Effect of power ultrasound application on aqueous extraction of phenolic compounds and antioxidant capacity from grape pomace (Vitis vinifera L.): Experimental kinetics and modeling

期刊

ULTRASONICS SONOCHEMISTRY
卷 22, 期 -, 页码 506-514

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.ultsonch.2014.05.027

关键词

Grape pomace; Winery by-products; Ultrasound-assisted extraction; Weibull model; Total phenolic content; Antioxidant capacity

资金

  1. Spanish Government (MICINN)
  2. European Regional Development Fund (FEDER) [DPI2012-37466-C03-02, AGL 2012-34627]
  3. Balearic Government [57/2011]

向作者/读者索取更多资源

The kinetics of both conventional (mechanical stirring, 200 rpm) and acoustic (55 +/- 5 kHz, 435 +/- 5 W/L) aqueous extraction of total phenolic content and antioxidant capacity from grape pomace by-products (Vitis vinifera L.) have been experimentally evaluated and modeled at different extraction temperatures (20, 35 and 50 degrees C). A gradual and significant increase of total phenolic content and antioxidant capacity of the extracts was observed as the temperature increased, the highest values being obtained in the case of the extraction assisted acoustically. According to the results, the acoustic assistance of the extraction process led to aqueous extracts with phenolic and antioxidant characteristics similar to those obtained with mechanical stirring, working under lower temperature conditions and during less operating time. Specifically, the conventional extraction of total phenolics at 35 and 50 degrees C did not differ significantly from extractions assisted with power ultrasound at 20 and 35 degrees C, respectively; and the acoustic process required approximately 3, 4 and 8 times less time, at 20, 35 and 50 degrees C, than the conventional extraction to obtain extracts with similar characteristics. The extraction curves obtained for total phenolic content and antioxidant capacity, measured by the ABTS and FRAP methods, were properly represented by a modified Weibull model for both conventional and acoustic extractions within the temperature range 20-50 degrees C, presenting an average percentage of explained variance >= 97.9%, and an average mean relative error <= 7.0%. A high correlation (r(2) >= 0.992) was observed between the experimental and simulated values for all the quality attributes in study. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据