Purpose The objectives of this study were to characterize the validity of algorithms to identify AF from electronic health data through a systematic review of the literature and to identify gaps needing further research. Methods Two reviewers examined publications during 1997-2008 that identified patients with atrial fibrillation (AF) from electronic health data and provided validation information. We abstracted information including algorithm sensitivity, specificity, and positive predictive value (PPV). Results We reviewed 544 abstracts and 281 full-text articles, of which 18 provided validation information from 16 unique studies. Most used data from before 2000, and 10 of 16 used only inpatient data. Three studies incorporated electronic ECG data for case identification or validation. A large proportion of prevalent AF cases identified by ICD-9 code 427.31 were valid (PPV 70%-96%, median 89%). Seven studies reported algorithm sensitivity (range, 57%-95%, median 79%). One study validated an algorithm for incident AF and reported a PPV of 77%. Conclusions The ICD-9 code 427.31 performed relatively well, but conclusions about algorithm validity are hindered by few recent data, use of nonrepresentative populations, and a disproportionate focus on inpatient data. An optimal contemporary algorithm would likely draw on inpatient and outpatient codes and electronic ECG data. Additional research is needed in representative, contemporary populations regarding algorithms that identify incident AF and incorporate electronic ECG data. Copyright (C) 2012 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据