Validity of Physical Activity Measures in Individuals After Total Knee Arthroplasty

期刊

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.apmr.2014.10.009

关键词

Accelerometry; Activities of daily living; Arthroplasty; replacement; knee; Energy metabolism; Reference standards; Rehabilitation; Validation studies

资金

  1. Central Research Development Fund
  2. Pepper Center Scholars Pilot Program [P30-AG024827]
  3. University of Pittsburgh, Pittsburgh, PA

向作者/读者索取更多资源

Objective: To determine the concurrent criterion-related validity of 2 activity monitors in comparison with the criterion method of indirect calorimetry in older adults after total knee arthroplasty (TKA). Design: Validation study. Setting: Subjects completed 9 increasingly demanding daily activities in a research laboratory; each activity was performed for 7 minutes, for a total of 80 minutes, while the activity monitors and criterion method were used concurrently. Participants: Subjects (N=21, 67% women) had a mean age +/- SD of 68 +/- 7 years and a body mass index of 29 +/- 4. Interventions: Not applicable. Main Outcome Measures: Energy expenditure (in kcal/min) measured by accelerometer-based and multisensor-based monitors and by a criterion method. Validity was assessed by the paired t test, intraclass correlation coefficient (ICC), and Bland-Altman plots comparing the measurements from the activity monitors with those of the criterion method. Results: Measurements from the accelerometer-based monitor were significantly lower than those of the criterion method across all walking and nonwalking activities. The underestimations ranged from 40% to 100%. The accelerometer-based monitor demonstrated small to moderate agreement compared with the criterion method (ICCs from 0 to .38). Measurements from the multisensor-based monitor were significantly lower than those of the criterion method during several nonwallcing activities; yet, the differences were minor (2%-19%). Measurements from the multisensor-based monitor during walking activities were not different compared with the criterion method. The multisensor-based monitor demonstrated moderate to excellent agreement with the criterion method (ICCs from .48 to .81). Conclusions: The multisensor-based monitor showed better criterion-related validity than the accelerometer-based monitor and should be considered as a tool to measure physical activity in individuals after TKA. (C) 2015 by the American Congress of Rehabilitation Medicine

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据